ATTRE MedoFrax MINI

Price for professionals only Log in to see the price

MEDOFRAX MINI

The latest generation of microneedle therapy with radiofrequency and vacuum technology, fractional RF. Effectively combats scars and rejuvenates.

Facebook
Email
Microneedle and fractional radiofrequency therapy

MEDOFRAX is the latest generation microneedle RF radio frequency device with vacuum function. It allows you to perform fractional microneedle and RF procedures, effectively fights scars and promotes skin regeneration.

MEDOFRAX can be carried out with the following procedures:

• Scar reduction
• Reduction of stretch marks
• wrinkle smoothing
• Improvement of facial contours
• lifting of drooping eyelids
• cheek lift
• reduction of eye bags
• Increasing skin elasticity
• Improvement of skin density and firmness
• stimulation of collagen fiber reconstruction
• tightening of the skin of the body (abdomen, arms, breasts)

How does RF microneedle RF therapy work?

Microneedle radio frequency (RF) therapy is the piercing of the skin with thin needles and at the same time heating it with radio waves. The needles used in the RF procedure also act as microelectrodes that transmit radio waves deep into the tissues.

As a result, the skin heats up to a temperature of 42-60 °C, causing collagen fibers to shrink. Simultaneous puncture and heating of tissues damages the treated skin and causes controlled inflammation. The procedure causes intensive skin regeneration processes and multidimensional rearrangements. In the treated area, young, firm skin is created. Radio waves accelerate and enhance the self-regenerating properties of the dermis, while the restored collagen fibers smooth, tighten the skin and give it elasticity.

Microneedle radiofrequency (RF) therapy works on the deep layers of the skin, promoting regeneration. It can be used on both the face and body. It reduces wrinkles, eliminates scars and stretch marks, improves skin density and firmness. Recommended for rejuvenating and rejuvenating procedures.

How does fractional RF therapy work?

Fractional RF therapy is a non-invasive procedure. Unlike microneedle RF, it does not violate the integrity of tissues. There are no needles or punctures. RF waves cause regenerative processes that warm the dermis, improve metabolism and microcirculation, stimulate fibroblasts to produce new collagen fibers.

The fractional RF procedure is recommended for people who are contraindicated in needle procedures (diabetics, people prone to scarring, and people who have difficulty healing). This is the best alternative to needle RF procedures.

Indications for microneedle RF therapy
  • postoperative, post-traumatic and acne scars
  • stretch marks
  • wrinkles
  • visible signs of aging
  • sagging skin
  • Lost facial contour

 

“Medofrax” is modern Microneedle Radio Frequency Wave Device with vacuum function . The device uses microneedle and RF technology, which allows you to perform fractional treatment with and without microneedles. The device is equipped with an innovative, US-made radio frequency wave generation module, which is incredibly efficient. In the case of For 50 W of power, it emits radio waves that are similar in energy to devices 150 W power . This module increases the “Medofrax” efficiency and the safety and efficiency of procedures.

Medofrax has light and thin manipulations. The device features an innovative cassette and manipulator connection system (no protruding, clumsy hose!). The easy design of the manipulations, the shape and the absence of a hose allow the device to be easy to use and ensure accurate coverage of the areas. Even long-term use does not tire the hand.

Microneedle cartridges

Medofrax is equipped with ultra-thin needles with a diameter of 0.2 mm. This allows you to drill precisely to a set depth. The depth of penetration can be adjusted from 0.4 to 4 mm . Needles also act as radiofrequency microelectrodes. The device is equipped with vacuum technology, which allows you to evenly and accurately insert needles even into sagging skin and hard-to-reach areas of the body (face, neck, décolleté). Medofrax offers a wide range of cartridges and adjustable parameters.

There is a choice of gold-insulated or non-insulated needles and four different sizes of cartridges. Disposable, sterile cartridges have 18, 25, 49 or 81 needles .

Most of the surfaces of insulated needles are plated with gold. Gold is impervious to radio waves. Radio waves heat the skin not along the entire length of the needle, but only around the uninsulated tip. Thus, radio waves work exactly where we want them to be, at a set depth. Isolated needles are less invasive, and recovery after the procedure is significantly faster.

Uninsulated needles emit radio waves along their entire length. They damage the tissues more and cause greater inflammation. Therefore, the recovery period after the procedure is longer than when using insulated needles.

Non-invasive fractional RF cartridges have rods (protrusions) through which radio waves propagate. Medofrax can be supplied with three different sizes of cartridges of this type. Available sizes: 3×3, 5×5 and 9×9.

Vacuum technology,monopolar and bipolar operating modes

MedoFrax is equipped with a vacuum technology . The vacuum creates negative pressure, which draws the skin fold into the microneedle cartridge. Localized negative pressure distracts the skin from the rest of the tissue. The needles automatically come out, stick into the skin and emit radio waves. Due to the negative pressure, the cartridge comes into better contact with the skin, even in hard-to-reach areas of the body (face, neck and bone tissue). The needles are inserted smoothly, evenly and precisely into the selected depth. Vacuum facilitates the treatment of sagging skin and reduces pain. The procedure is significantly less painful than using devices without this technology.

Bipolar mode

Medofrax offers bipolar operation. In this mode, 50% of the needle is positively charged and the remaining 50% is negatively charged. This ensures that the radio frequency only works at the depth of the needle and does not penetrate deep into the tissues. Therefore, this mode is more suitable for facial treatments.

Unipolar mode

In monopoly mode, the needles are positively charged. The client holds the so-called passive electrode, which acts as a negative charge. This allows radio waves to penetrate the entire body and perform deep healing.

TECHNICAL DATA
The power of the device: 500 W
RF wave frequency: 2 MHz
RF power: Up to 50 W
RF modes: Bipolar, unipolar
Pulse duration: 10-900 ms
Energy regulation: 1-10
Operating modes: Automatic, stand-alone
Manipulations: cooling, passive electrode, fractional RF, microadditive RF
Needle thickness: 0.2 mm (extra fine needles)
The depth of the puncture: 0.4-4 mm
Needles: Insulated, Non-insulated
Microdata cartridges: M-18, M-25, M-49, M-81
RF fractional needleless cartridges: F-3×3, F-5×5, F-9×9
Vacuum levels: 1-4 (can be switched off)
Engine type: Precision stepper motor
Display: 10.4″ touchscreen, HD colour
Dimensions: 65,5 x 48,5 x 52,5 cm
Weight: 17.5 kg

 

Description

TECHNICAL DATA
The power of the device: 500 W
RF wave frequency: 2 MHz
RF power: Up to 50 W
RF modes: Bipolar, unipolar
Pulse duration: 10-900 ms
Energy regulation: 1-10
Operating modes: Automatic, stand-alone
Manipulations: cooling, passive electrode, fractional RF, microadditive RF
Needle thickness: 0.2 mm (extra fine needles)
The depth of the puncture: 0.4-4 mm
Needles: Insulated, Non-insulated
Microdata cartridges: M-18, M-25, M-49, M-81
RF fractional needleless cartridges: F-3×3, F-5×5, F-9×9
Vacuum levels: 1-4 (can be switched off)
Engine type: Precision stepper motor
Display: 10.4″ touchscreen, HD colour
Dimensions: 65,5 x 48,5 x 52,5 cm
Weight: 17.5 kg

 